{"product_id":"elitech-refrigerant-leak-detector-ild-100h-heated-diode-handheld-with-tft-display-0-1-oz-yr","title":"Elitech Refrigerant Leak Detector ILD-100H Heated-Diode Handheld with TFT Display, 0.1 oz\/yr","description":"\u003cp\u003e\u003cstrong\u003eThe Elitech ILD-100H is a handheld heated-diode refrigerant leak detector engineered to find halogen-based refrigerants quickly and accurately.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCompact and purpose-built for HVAC technicians, the ILD-100H uses a heated diode sensor and a clear TFT display to locate leaks from a wide range of halogenated gases including CFCs, HCFCs, HFCs and newer blends like R1234yf. Its adjustable sensitivity, rapid response time and straightforward controls let users scan equipment, piping and fittings with confidence while monitoring battery and sensitivity status on-screen.\u003c\/p\u003e\n\n\u003ch3\u003eHow fast and sensitive is the ILD-100H at finding refrigerant leaks?\u003c\/h3\u003e\n\u003cp\u003eThe detector offers high, medium and low sensitivity settings and can detect leaks down to 0.1 oz\/year at its maximum setting. Response is almost immediate, with the sensor reacting within about one second when refrigerant is present.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMaximum sensitivity: detectable to 0.1 oz\/year\u003c\/li\u003e\n  \u003cli\u003eAdjustable sensitivity: High \/ Medium \/ Low\u003c\/li\u003e\n  \u003cli\u003eResponse time: approximately 1 second on detection\u003c\/li\u003e\n  \u003cli\u003eQuick front-panel buttons to change sensitivity on the fly\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhich refrigerants and gases does this detector identify?\u003c\/h3\u003e\n\u003cp\u003eThe ILD-100H detects a broad range of halogenated refrigerants and many blends used in modern HVAC systems. It covers legacy gases and newer formulations, making it suitable for service, retrofit and leak survey tasks across different equipment types.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports CFCs, HCFCs and HFCs\u003c\/li\u003e\n  \u003cli\u003eDetects HFOs such as R1234yf and blends like AZ-50, HP62, MP39\u003c\/li\u003e\n  \u003cli\u003eWorks with commonly used refrigerants: R11, R22, R404A, R410A, R600a and others\u003c\/li\u003e\n  \u003cli\u003eResponsive to mixed and blended halogenated refrigerants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat features help technicians use it effectively on the job?\u003c\/h3\u003e\n\u003cp\u003eThe ILD-100H pairs a heated diode sensor with a TFT screen that displays sensitivity, leak alerts and battery life for faster decision-making. Ergonomic controls let you mute the buzzer or change sensitivity instantly without interrupting inspections.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTFT screen shows real-time sensitivity, alerts and battery status\u003c\/li\u003e\n  \u003cli\u003eTwo front buttons for quick sensitivity changes and buzzer mute\u003c\/li\u003e\n  \u003cli\u003eHeated diode sensor for improved detection accuracy versus older sensor types\u003c\/li\u003e\n  \u003cli\u003eLightweight handheld body for easy maneuvering around coils and fittings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow reliable and serviceable is the Elitech detector?\u003c\/h3\u003e\n\u003cp\u003eElitech provides one-year warranty coverage and offers customer support to help with troubleshooting and parts. The heated diode sensor is designed for stable operation across a range of halogenated refrigerants, reducing false readings common with older sensor technologies.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOne-year warranty included\u003c\/li\u003e\n  \u003cli\u003e24\/7 customer service availability advertised by Elitech\u003c\/li\u003e\n  \u003cli\u003eDurable heated diode sensor minimizes cross-sensitivity issues\u003c\/li\u003e\n  \u003cli\u003eSimple controls and clear display reduce operator error\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWho is this for: The Elitech ILD-100H is aimed at HVAC technicians, service contractors and facilities maintenance professionals who need a portable, reliable way to find halogen refrigerant leaks across residential and commercial equipment. It’s particularly useful for users who require fast response, adjustable sensitivity and clear on-device status indicators while inspecting lines, valves, fittings and coil assemblies.\u003c\/p\u003e\n\u003csection class=\"product-faq-snippet\"\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Can the ILD-100H detect R1234yf and modern HFO blends?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: Yes. The ILD-100H detects HFOs like R1234yf and many blended refrigerants used in current systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: How do I change the detector's sensitivity during inspections?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: Use the two front-panel buttons to toggle High\/Medium\/Low sensitivity or mute the buzzer instantly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e","brand":"Elitech","offers":[{"title":"Default Title","offer_id":48082669666462,"sku":"B07K6JNTYG","price":180.48,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0781\/2041\/9486\/files\/elitech-ild-100h-front-view.jpg?v=1785811788","url":"https:\/\/northtrailauto.ca\/products\/elitech-refrigerant-leak-detector-ild-100h-heated-diode-handheld-with-tft-display-0-1-oz-yr","provider":"North Trail Auto","version":"1.0","type":"link"}