{"product_id":"lichamp-a2l-refrigerant-charging-hose-60-5-ft-yellow-1-4-sae-lh-to-rh-ptfe-sealed-800-psi-working","title":"Lichamp A2L Refrigerant Charging Hose 60\" (5 ft) Yellow — 1\/4\" SAE LH to RH, PTFE-Sealed, 800 PSI Working","description":"\u003cp\u003e\u003cstrong\u003eLichamp's yellow 60-inch A2L refrigerant charging hose connects 1\/4\" SAE left-hand and right-hand fittings for safe charging of R32 and R454B systems.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThis heavy-duty charging hose is built for technicians who work with lower-flammability (A2L) refrigerants and need a dependable, flexible line that reaches into tight or awkward service locations. With a 5-foot length, left-hand thread compatibility for A2L fittings, and rugged construction rated to high pressures and wide temperatures, it’s aimed at HVAC, refrigeration, and automotive applications where reliability and leak resistance matter.\u003c\/p\u003e\n\n\u003ch3\u003eWhat makes this hose suitable for A2L refrigerants like R32 and R454B?\u003c\/h3\u003e\n\u003cp\u003eThe Lichamp hose uses left-hand flared 1\/4\" SAE threads on the A2L end to match industry-standard fittings for lower-flammability refrigerants, preventing accidental cross-connection. The other end is a standard right-hand 1\/4\" SAE, enabling use with common gauges and service tools. Materials and sealing systems are selected to meet the demands of A2L service situations without compromising safety.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eLeft-hand 1\/4\" SAE flared thread for A2L refrigerant connections\u003c\/li\u003e\n  \u003cli\u003eOpposite end with standard 1\/4\" SAE threading for tool compatibility\u003c\/li\u003e\n  \u003cli\u003ePTFE seals and brass fittings reduce leak risk\u003c\/li\u003e\n  \u003cli\u003eYellow jacket for quick visual identification of A2L line\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow durable is the hose under pressure and temperature extremes?\u003c\/h3\u003e\n\u003cp\u003eThis hose is engineered for demanding environments, with a high burst and working pressure rating to withstand service stresses. The rubber outer and brass fittings resist wear, while PTFE sealing adds longevity by maintaining a tight connection under load. Temperature ratings cover most field conditions encountered in HVAC and automotive work.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e4000 PSI burst pressure and 800 PSI working pressure\u003c\/li\u003e\n  \u003cli\u003eServiceable from approximately -20°F to 180°F (-29°C to 82°C)\u003c\/li\u003e\n  \u003cli\u003eHigh-grade rubber body resists abrasion and chemicals\u003c\/li\u003e\n  \u003cli\u003eBrass fittings add corrosion resistance and mechanical strength\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDoes the hose make on-site work easier in cramped spaces?\u003c\/h3\u003e\n\u003cp\u003eThe 5-foot length gives technicians reach to access deep or awkward locations without stretching equipment or creating unsafe kinks. A 45-degree angled end helps line up adapters and gauge ports, and the heavily knurled coupling nut allows quick, tool-free hand tightening for fast turnarounds. These design choices reduce fumbling and speed up standard charging or recovery tasks.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e60-inch length for reach into engine bays and tight cabinets\u003c\/li\u003e\n  \u003cli\u003e45° angled fitting eases adapter and gauge alignment\u003c\/li\u003e\n  \u003cli\u003eDeeply knurled coupling nut for reliable hand-tight connections\u003c\/li\u003e\n  \u003cli\u003eFlexible construction minimizes kinking when routed around components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWho this hose is for: a practical choice for HVAC technicians, refrigeration service pros, and automotive A\/C specialists who handle A2L refrigerants and need a robust, easily identified charging line. It’s also useful for maintenance shops working on commercial freezers, residential heat pumps, or automotive systems where left-hand A2L fittings are required. If you want a durable, leak-resistant hose that reaches into tight service areas and matches modern refrigerant fittings, this Lichamp A2L charging hose is designed for that work.\u003c\/p\u003e\n\u003csection class=\"product-faq-snippet\"\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Is this hose compatible with R32 and R454B?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: Yes. It has a 1\/4\" left-hand SAE fitting for A2L refrigerants like R32 and R454B and a standard right-hand 1\/4\" SAE on the other end.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: What are the pressure and temperature ratings?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: Working pressure is 800 PSI, burst pressure 4000 PSI, and temperature range is about -20°F to 180°F.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e","brand":"Lichamp","offers":[{"title":"Default Title","offer_id":48085099020446,"sku":"B0FJS184CD","price":34.98,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0781\/2041\/9486\/files\/lichamp-front-packaging-and-fittings.jpg?v=1785867446","url":"https:\/\/northtrailauto.ca\/products\/lichamp-a2l-refrigerant-charging-hose-60-5-ft-yellow-1-4-sae-lh-to-rh-ptfe-sealed-800-psi-working","provider":"North Trail Auto","version":"1.0","type":"link"}